Skip to content

ADA Counter Height Requirements: Sales Counters, Sinks and Work Surfaces

New service counter under construction with a lowered section and open knee space beneath

ADA counter height is 36 inches maximum at sales and service counters, 38 inches at check-out counters, and 28 to 34 inches at dining surfaces, work surfaces and sinks, measured from the finish floor.

Key takeaways

  • A sales or service counter needs a portion no higher than 36 inches that is 36 inches long for a side (parallel) approach or 30 inches long with knee space for a forward approach, under 2010 ADA Standards §904.4.
  • Check-out aisle counters may reach 38 inches, with edge protection no more than 2 inches higher, so 40 inches at the lip (Justice Department text of the 2010 ADA Standards, §904.3.2).
  • Dining surfaces, bars, work surfaces and tray slides sit between 28 and 34 inches, and at least 5% of seating and standing spaces must comply (2010 ADA Standards §902.3, §226.1, §904.5.2).
  • Sinks and lavatories: the front of the rim or counter is 34 inches maximum, with knee clearance 27 inches high, and at least 5% of each sink type per room must comply (U.S. Access Board guide to lavatories and sinks).
  • An existing counter that met the 1991 Standards and has not been altered since March 15, 2012 keeps safe harbor under 28 CFR 36.304(d)(2)(i).
  • A Texas city registered a $71,066 job in 2025 to convert a standing clerk counter to seated height (TDLR record TABS2025020639).

What is the ADA counter height for each type of counter?

There is no single ADA counter height. The 2010 ADA Standards set a limit per element: 36 inches for the accessible part of a sales or service counter, 38 inches for a check-out counter, and 34 inches for dining surfaces, work surfaces, tray slides and sinks, with a 28 inch floor on tables and work surfaces. Each height runs from the finish floor to the top surface.

ElementHeight ruleLength or clearance2010 section
Sales or service counter, parallel approach36 in maxPortion 36 in long min; 30 by 48 in clear floor space alongside904.4.1, 305.3
Sales or service counter, forward approach36 in maxPortion 30 in long min; knee space 27 in high, 30 in wide904.4.2, 306
Counter shorter than 36 inWhole counter 36 in maxNone beyond height904.4.1 exception
Check-out aisle counter38 in max; edge protection 2 in max above it (40 in)Aisle per 403904.3.2
Check writing surface at a check-out28 to 34 inHeight rule only904.3.3, 902.3
Dining surface, bar, lunch counter, work surface28 in min, 34 in maxKnee space 27 in high, 30 in wide902.2, 902.3
Children’s dining or work surface26 in min, 30 in maxKnee space 24 in min902.4
Tray slide in a food service line28 in min, 34 in maxNone stated904.5.2
Lavatory or sinkFront of rim or counter 34 in maxKnee 27 in min; toe space 9 in high606.3, 306
Kitchen work surface in an accessible dwelling unit34 in max, or adjustable 29 to 36 in30 in wide section804.3
Self-service shelves, dispensers, operable partsWithin 15 in to 48 in reachSee reach table below308, 904.5.1
ADA counter heights on one scale Reach range: 48 in max high, 15 in min low (308) 9 in 15 in 34 in 36 in 38 in 40 in 48 in 0 28 to 34 in Knee space 27 in min high (306) 34 in max rim Knee 27 in min Toe 9 in 36 in max 36 in long (parallel) or 30 in long with knee space (forward) 38 in max + 2 in edge Edge protection top 40 in max Dining or work surface 2010 ADA Standards 902.3 Lavatory or sink 2010 ADA Standards 606.3 Sales or service counter 2010 ADA Standards 904.4 Check-out counter 2010 ADA Standards 904.3.2 All heights measured from the finish floor to the top of the surface (sinks: front of rim or counter, whichever is higher).
Every ADA counter height on one scale, measured from the finish floor: 28 to 34 in for dining and work surfaces (902.3), 34 in for sinks (606.3), 36 in for sales counters (904.4) and 38 in plus a 2 in edge for check-out counters (904.3.2). Source: 2010 ADA Standards, accessed November 2026.

Section 104.1.1 says field tolerances do not apply where a rule is a range with stated end points, such as 28 to 34 inches, and its advisory says tolerances are not meant for design work. As of November 2026, the 2010 Standards are the federal rule for work permitted on or after March 15, 2012 (28 CFR 36.406(a)(3)). This page is general information, not legal advice.

What are the rules for sales, service and check-out counters?

A sales or service counter needs one accessible portion 36 inches high or lower. If the customer pulls alongside (parallel approach), that portion is 36 inches long. If the customer rolls under it (forward approach), 30 inches is enough, but knee and toe space is required. Section 227.3 asks for at least one of each counter type, so order and pick-up counters each need one.

RuleParallel approachForward approachSource
Accessible length36 in min30 in min2010 ADA Standards 904.4.1, 904.4.2
Height36 in max36 in max904.4.1, 904.4.2
Clear floor space30 by 48 in, long side along the counter30 by 48 in, facing the counter305.3
Knee clearanceNot required27 in high, 30 in wide, 11 in deep min at 9 in above floor306.3
Toe clearanceNot required9 in high, 17 in deep min, 25 in max306.2
Depth of the accessible portionSame depth as the counter topSame depth as the counter top904.4

How deep must the lowered section be?

Section 904.4 requires the accessible portion to run the same depth as the counter top. The Justice Department’s commentary in 28 CFR Part 36, Appendix B says that on a split-height counter the rule covers only the customer side, the lowered section must be staffed with the same level of service, and its clear floor space must stay free of merchandise.

Two exceptions apply. If the whole counter is shorter than 36 inches, the entire counter must be 36 inches high or lower (904.4.1 exception). In alterations where a full section would cut the number of work stations or mail boxes, a 24 inch long section is allowed, with the clear floor space centered on it (904.4 exception).

How high can a check-out aisle counter be?

A check-out counter can be 38 inches high, and any edge protection on the aisle side can rise 2 inches above the counter surface (904.3.2). A check writing surface, where provided, goes at 28 to 34 inches (904.3.3). The number of accessible aisles follows Table 227.2, counted separately for each function such as express lanes.

Check-out aisles of each functionAccessible aisles requiredSource
1 to 412010 ADA Standards Table 227.2
5 to 82Table 227.2
9 to 153Table 227.2
16 and over3, plus 20% of additional aislesTable 227.2
Selling space under 5,000 sq ftNo more than 1 required227.2 exception

Retail fit-outs that add a cash wrap or check-out lane carry Table 227.2 onto the drawings. The rest of a store build is covered in our guide to retail construction.

How high can tables, bars and work surfaces be?

Dining surfaces and work surfaces must be 28 to 34 inches high with a forward approach and knee and toe space (902.2, 902.3). Advisory 902.1 lists bars, tables, lunch counters and booths as dining surfaces, and writing surfaces, coupon counters and baby changing tables as work surfaces. At least 5% of seating and standing spaces at dining surfaces must comply (226.1).

The 1991 Standards handled bars differently: a counter over 34 inches needed a 60 inch long accessible portion or service at accessible tables in the same area (1991 ADAAG 5.2). The 2010 rule counts seats and standing spaces instead, and the Justice Department said in Appendix B that basing the count on spaces rather than tables gives designers room to disperse them (226.2).

Three related limits catch fit-outs. Children’s tables run 26 to 30 inches with 24 inch knee space (902.4). Tray slides in a cafeteria line run 28 to 34 inches, and 50% of self-service shelves, at least one of each type, must sit within reach (904.5.2, 227.4). Work surfaces used only by employees are outside 226.1, but Advisory 226.1 names commercial kitchen counters, reception counters and teller windows as items an employer may need to adjust as a reasonable accommodation.

Restaurant layouts that mix a bar, a counter and table seating apply the 5% count across all three (226.1, 226.2). The trades involved are covered on our page about restaurant build-out contractors.

What is the ADA sink height, and which sinks must comply?

ADA sink height is 34 inches maximum, measured to the front of the rim or counter, whichever is higher (606.3). Below it you need knee clearance at least 27 inches high and 30 inches wide, toe space up to 9 inches, and a 30 by 48 inch clear floor space (606.2, 306, 305.3). At least 5% of each sink type per accessible room, and no fewer than one, must comply (212.3).

Sink ruleRequirementSection
Rim or counter height34 in max at the front606.3
Knee clearance27 in high min, 30 in wide; 11 in deep at 9 in, 8 in deep at 27 in306.3
Multi-bowl sinkOnly one bowl needs knee and toe clearance606.2 exception 7
Kitchen sink with no cooktop or range, wet barParallel approach allowed606.2 exception 1
FaucetsOne hand, 5 lbf max; metering faucets open 10 seconds min309.4, 606.4
PipesInsulated or configured to prevent contact606.5
Mop or service sinksExempt from 212.3212.3 exception
Residential kitchen sinkAdjustable 29 to 36 in allowed606.3 exception 2

Section 106.5 defines employee work areas as spaces used only by employees and only for work, and says break rooms and kitchenettes are not employee work areas. So a break room sink counts toward 212.3, though a parallel approach is allowed where there is no cooktop. A prep or dish sink used only by kitchen staff falls under 203.9, which the Access Board sink guide confirms. Food Code sink types and drains are in our commercial kitchen sink guide.

The height numbers leave little room for the bowl. CB&C arithmetic: 34 inches minus 27 inches leaves 7 inches for the counter, bowl and drain where knee clearance must be at least 8 inches deep at the 27 inch line (306.3.3). The Access Board guide also flags garbage disposals that intrude into knee space and suggests rear-drain or two-bowl sinks. Toilet room layout around the lavatory is outside this page.

What reach ranges apply above a counter?

Anything a customer must reach over a counter, such as shelves, dispensers or controls, falls under section 308. An unobstructed reach runs from 15 inches up to 48 inches above the floor. Reaching across a counter lowers the ceiling: 44 inches forward over a counter deeper than 20 inches, and 46 inches sideways over a counter deeper than 10 inches.

Reach situationHigh limitLow limitConditionSection
Forward, unobstructed48 in15 inNone308.2.1
Forward, over counter up to 20 in deep48 inNone statedClear floor space extends under the counter308.2.2
Forward, over counter 20 to 25 in deep44 inNone stated25 in reach depth max308.2.2
Side, unobstructed48 in15 inObstruction up to 10 in deep allowed308.3.1
Side, over counter up to 10 in deep48 inNone statedCounter 34 in high max308.3.2
Side, over counter 10 to 24 in deep46 inNone statedCounter 34 in high max, 24 in deep max308.3.2
1991 Standards side reach (safe harbor only)54 in9 inUnaltered 1991 elements1991 ADAAG 4.2.6
ADA reach ranges over a counter Forward reach over a counter 2010 ADA Standards 308.2.2 48 in max depth up to 20 in 44 in max depth 20 to 25 in Clear floor space extends under the counter Unobstructed: 15 in min to 48 in max (308.2.1) Side reach over a counter 2010 ADA Standards 308.3.2 48 in max depth up to 10 in 46 in max depth 10 to 24 in Counter 34 in max high, 24 in max deep Unobstructed: 15 in min to 48 in max (308.3.1) 34 in Heights above the finish floor. The 1991 Standards allowed a 54 in side reach; it survives only for unaltered 1991 elements. Operable parts within these ranges must work with one hand and 5 lbf max (309.4).
Reaching across a counter lowers the limit: forward reach drops from 48 in to 44 in past 20 in of depth (308.2.2), side reach from 48 in to 46 in past 10 in over a counter 34 in high max (308.3.2). Source: 2010 ADA Standards, accessed November 2026.

The Justice Department noted in Appendix B that the 2010 Standards cut maximum side reach from 54 inches to 48 inches, and that facilities complying with the 54 inch rule need not change unless they alter the element. Operable parts on or above a counter must also work with one hand and no more than 5 pounds of force (309.4).

How many counters, tables and sinks have to comply?

Not every counter has to be low. The 2010 Standards require one accessible sales or service counter of each type, a set number of check-out aisles, 5% of dining seats and public work surfaces, 5% of each sink type per room, and 50% of self-service shelves in food lines. Where a percentage leaves a fraction, section 104.2 rounds up to the next whole number.

ElementMinimum that must complyDispersionSection
Sales and service counters1 of each type (order, pick-up, returns are separate types)Dispersed if counters are227.3
Check-out aislesTable 227.2, per functionDispersed if aisles are227.2
Dining surfaces5% of seating and standing spacesThroughout the dining space226.1, 226.2
Work surfaces used by the public5%Throughout the space226.1
Self-service shelves in food lines50%, at least 1 of each typeNone stated227.4
Sinks5%, at least 1 of each type per accessible roomNone stated212.3
Employee-only work areasApproach, enter and exit onlyNone203.9
Worked caseInputsCalculationAccessible count
Restaurant dining room130 seats at tables and a bar130 x 5% = 6.5, rounded up (104.2)7 seating spaces
Grocery store over 5,000 sq ft18 standard check-out aisles3 + 20% x (18 minus 15) = 3.6, rounded up4 aisles
Store under 5,000 sq ft of selling space3 check-out aisles227.2 exception1 aisle
Multi-user restroom3 lavatories of one type3 x 5% = 0.15, no fewer than one1 lavatory
Clinic front desk1 check-in counter, 1 check-out counterOne of each type (227.3)2 accessible sections

A clinic that splits check-in and check-out into separate counters has two counter types under 227.3, as in the last row. The rest of that fit-out is covered in our guide to medical office construction.

How do the IBC and ICC A117.1 differ from the ADA Standards?

Local building codes based on the International Building Code (IBC) point to the ICC A117.1 standard, not the ADA Standards. The 2021 IBC section 1110.13.2 requires one accessible sales or service counter or window of each type, and A117.1-2017 adds rules the ADA lacks, including a 26 inch minimum height at parallel-approach counters. An ICC presentation on the 2017 edition notes that code officials enforce the adopted building code, not the ADA.

Item2010 ADA StandardsICC A117.1-2017 (2021 IBC)Source
Parallel-approach counter height36 in max, no minimum26 in min to 36 in maxICC-hosted 2021 changes deck, A117.1 904.3.2
Barrier between staff and customerNo height limit; voice communication where security glazing exists (904.6)43 in max; transparent security glazing allowed aboveA117.1 904.3.1
Space above the accessible counterNot stated12 in min to any projecting objectA117.1 904.3.2, 904.3.3
Clear floor space30 by 48 in30 by 52 in in new construction and additions; existing buildings keep 48 inICC 2017 changes deck
Turning space60 in circle (304.3.1)67 in in new constructionICC 2017 changes deck
Sales and service windowsCounters onlyWindows covered even without a counterWashington SBCC 2021 IBC worksheet
Reach range, knee and toe clearance308, 306No change in 2017ICC 2017 changes deck

Where both apply, design to whichever is stricter on each line: a 36 inch high parallel counter section that is 30 by 52 inches clear, with nothing projecting within 12 inches above it, meets both. Ask the plans examiner which A117.1 edition your jurisdiction adopted, because a jurisdiction still on the 2009 edition will not enforce the 2017 rows. A code official can measure these at the final inspection that precedes a certificate of occupancy.

What does lowering a counter cost?

Public records put counter jobs between $1,995.31 for a one-week federal desk height change in 2017 and $71,066 for a city clerk counter conversion in Texas in 2025. Scope drives the spread: adjusting existing millwork, buying a new counter, or rebuilding the counter with glazing, doors and finishes. None of these records is a quote for your project.

Public recordScopeSizeCostDateSource
City of Universal City, Bexar County, TXConvert standing-height customer service counter to sitting height518 sq ft$71,066 (estimated)Jun to Jul 2025TDLR TABS2025020639
Plano Municipal Building, TXReplace service counters in 2 departments1,000 sq ft$63,000 (estimated)May to Jul 2021TDLR TABS2021009096
McKinney Public Safety, TXAdd a new transaction window to the lobby195 sq ft$60,000 (estimated)Dec 2020 to Jan 2021TDLR TABS2021006284
Levin U.S. Courthouse, Detroit, MINew ADA counter, new doorway, panels, laminate, paint, signsNot stated$31,800Feb to Jun 2016USAspending GSP0516SV7090
Sweetgrass land port of entry, MTADA desk renovation and plexiglassNot stated$25,738Sep to Dec 2018USAspending 47PJ0018P0217
Luke Air Force Base, AZTwo custom service counters, 112 in W x 37 in D x 48 in H, with lift gate (supply)2 units$9,300.64Aug to Oct 2020USAspending FA488720P0060
USDA Farm Service Agency, Pendleton County, WVTwo service counters, 42 in high: $4,250 and $3,990 (furniture)127.75 in and 96 in long$8,840Sep to Dec 2016USAspending AG3151P160329
Russell B. Long Courthouse, Baton Rouge, LARaise front desk counter height to match nearby counters1 desk$1,995.31Feb 2017USAspending GSP0717UT0015
Public-record cost of counter jobsBar chart of eight public counter jobs from $1,995.31 for a desk height change to $71,066 for a seated clerk counter conversion$Universal City TX: convert standing to sea71,066Plano TX: replace service counters in 2 de63,000McKinney TX: new lobby transaction window,60,000Detroit MI courthouse: new ADA counter plu31,800Sweetgrass MT port: ADA desk renovation an25,738Luke AFB AZ: two custom service counters, 9,301Pendleton County WV: two 42 in service cou8,840Baton Rouge LA courthouse: raise front des1,995
Eight public counter jobs ranged from $1,995.31 (Baton Rouge, 2017) to $71,066 (Universal City, Texas, 2025); Texas figures are registered estimates. Sources: TDLR TABS and USAspending.gov, accessed November 2026.

CB&C arithmetic on those records: the Universal City conversion works out to $137.19 per square foot of registered area ($71,066 / 518), McKinney to $307.69 ($60,000 / 195), and Plano to $31,500 per department. The 2016 USDA counters cost about $399 and $499 per linear foot. Texas registers only jobs estimated at $50,000 or more (16 TAC §68.50(a)), so TABS shows the larger end of counter work.

TDLR TABS record TABS2025020639 showing a $71,066 estimate to convert a standing counter to sitting height
Texas TDLR TABS record TABS2025020639: City of Universal City, estimated cost $71,066, 518 sq ft, scope “Covert standing height customer service counter to sitting height” (spelling as filed). Project page accessed November 2, 2026.

A stand-alone counter job can be priced by a commercial renovation contractor. Inside a larger fit-out, the counter sits in the millwork scope priced by tenant improvement contractors. Either way, the shop drawing should show the lowered section length, approach type and knee space depth (904.4, 306), and the finished height belongs on the punch list.

Is there a tax credit for lowering a counter?

An eligible small business can claim 50% of barrier removal spending between $250 and $10,250, up to $5,000 a year, on IRS Form 8826. Eligible means gross receipts of $1 million or less, or 30 or fewer full-time employees, in the prior year. Barrier removal at a facility first placed in service after November 5, 1990 does not qualify, and credited dollars cannot also be deducted.

Form 8826 lineExample amountRule
1. Eligible access expenditures$12,000Counter lowering in an older building
2. Minimum amount$250Fixed on the form
3. Line 1 minus line 2$11,750Arithmetic
4. Maximum amount$10,000Fixed on the form
5. Smaller of line 3 or line 4$10,000Arithmetic
6. Line 5 x 50%$5,000Credit, capped at $5,000
Remaining spend$7,000May qualify for the barrier removal deduction, capped at $15,000 a year (26 U.S.C. §190(c))

Ask your CPA two questions before you sign the contract: whether the building was placed in service before November 6, 1990, and whether the $7,000 balance in a case like the one above should go to the section 190 deduction or be depreciated. Both answers change the after-tax cost of a $12,000 counter job.

Which rule applies to your counter?

Start with who uses the element, then what it is, then whether it is new or existing. Employee-only work areas need approach, entry and exit only. Customer-facing counters, aisles, dining surfaces and sinks each have their own height and count. An unaltered element that met the 1991 Standards keeps safe harbor, while new work and alterations follow the 2010 Standards.

IfThenSection
The element is used only by employees for workProvide approach, entry and exit; adjust on request203.9, Advisory 226.1
Customers pull alongside a sales or service counterPortion 36 in high max, 36 in long min, 30 by 48 in clear floor space904.4.1
Customers face the counter and roll under itPortion 36 in high max, 30 in long min, knee and toe space904.4.2
The whole counter is shorter than 36 inEntire counter 36 in high max904.4.1 exception
An alteration would cut work stations or mail boxes24 in long accessible section allowed904.4 exception
It is a check-out aisleCounter 38 in max, edge 2 in above it max904.3.2
It is a table, bar or public work surface28 to 34 in on 5% of seating and standing spaces902.3, 226.1
It is a public or break room sinkRim 34 in max, knee 27 in, 5% of each type606.3, 212.3, 106.5
The element met the 1991 Standards and is not being alteredNo change required (safe harbor)28 CFR 36.304(d)(2)(i)
Your jurisdiction enforces A117.1-2017Also 26 in min parallel height, 43 in barrier max, 30 by 52 in clear spaceA117.1 904.3, 305
Which ADA counter height rule applies 1. Is it used only by employees for work? (staff side of a counter, prep counter, office desk) Yes: 203.9 applies Approach, enter and exit only. Adjust on request as a reasonable accommodation (Advisory 226.1). Yes No 2. Which element is it? Sales or service counter 36 in max high 36 in long (parallel) or 30 in long + knee space (forward), 904.4 One of each type, 227.3 Check-out aisle Counter 38 in max Edge protection 2 in max, top 40 in max, 904.3.2 Count per Table 227.2 Dining, bar or work surface 28 in min to 34 in max Knee space 27 in min 902.3 and 306 5% of seating and standing spaces, 226.1 Sink or lavatory Rim or counter 34 in max Knee space 27 in min 606.3 and 306 5% of each type, no fewer than one, 212.3 3. Existing element that met the 1991 Standards and is not being altered? (for example, a 36 in high counter section built in 2005) Yes: safe harbor 28 CFR 36.304(d)(2)(i): no change needed until you alter it (1991 side reach 54 in still accepted) No: build to 2010 Standards New work and alterations: 2010 rules (36.406). Existing barriers: remove where readily achievable (36.304). Yes No
Three questions decide the rule: employee-only use (203.9), element type (904.4, 904.3.2, 902.3, 606.3) and whether an unaltered element met the 1991 Standards (28 CFR 36.304(d)(2)(i)). Sources: 2010 ADA Standards and 28 CFR Part 36, accessed November 2026.

What do common counter height guides get wrong?

Two top-ranking guides we read in November 2026 state rules the text does not contain, and several 1991 figures still circulate. The table sets six of them against the primary text. The pattern is a mix of 1991 and 2010 values: 29 inch sink aprons, 19 inch deep knee space, 54 inch side reach and 60 inch bar sections are all 1991 rules.

Claim or older figureWhat the primary source saysSource
Check-out counters are 36 in max (a law-firm guide updated April 2025)38 in max, plus edge protection up to 2 in2010 ADA Standards 904.3.2
Accessible counters need a 24 in minimum depth (same guide)No minimum depth; the accessible portion matches the counter top depth. 24 in is an alteration length exception904.4
Sink knee clearance of 29 in (1991 figure)27 in min (306.3); 29 in was the 1991 apron rule1991 ADAAG 4.19.2; 2010 306.3
Knee space under a sink is 19 in deep (a sink maker’s guide)11 in deep at 9 in and 8 in deep at 27 in; 19 in was the 1991 table rule1991 ADAAG 4.32.3; 2010 306.3.3
Bars need a 60 in lowered section (a food-service retailer guide, per its search listing)5% of seating and standing spaces at 28 to 34 in1991 ADAAG 5.2; 2010 226.1
Side reach of 54 in (1991 figure)48 in max; 54 in survives only for unaltered 1991 elements2010 308.3.1; 28 CFR 36.304(d)(2)(i)

Restroom lavatories sit inside the wider toilet room rules explained in our ADA bathroom requirements guide.

How we compiled this

In November 2026, CB&C editors read 12 primary documents: the 2010 ADA Standards (Access Board and Justice Department copies), the Access Board sink guide, the 1991 Standards, 28 CFR 36.304, 36.406 and Part 36 Appendix B, two ICC documents on A117.1-2017 and the 2021 IBC, a Washington State Building Code Council worksheet, IRS Form 8826, 26 U.S.C. §190 and 16 TAC §68.50. We added 3 Texas TABS registrations and 5 USAspending awards for cost. We did not review state amendments such as California Building Code Chapter 11B; check your state’s adopted code.

Frequently asked questions

Is ADA counter height 34 or 36 inches?

Both, for different elements. Sales and service counters need a section 36 inches high or lower (2010 ADA Standards §904.4). Dining surfaces, bars, work surfaces, tray slides and sinks top out at 34 inches (§902.3, §904.5.2, §606.3). Check-out aisle counters may reach 38 inches, with edge protection up to 2 inches above that (§904.3.2).

What is the ADA height for a reception desk?

A reception or check-in desk where visitors are served is a service counter, so one section must be 36 inches high or lower: 36 inches long for a side approach, or 30 inches long with knee space for a forward approach (§904.4). The staff side is an employee work area under §203.9. Under ICC A117.1-2017, any barrier between staff and visitor is capped at 43 inches, though clear security glazing may rise above it.

Do break room sinks have to meet ADA height?

Yes, in most cases. Section 106.5 of the 2010 ADA Standards says break rooms and kitchenettes are not employee work areas, so at least 5% of each sink type, and no fewer than one, must have a 34 inch rim and knee space (§212.3, §606.3). Where the room has no cooktop or range, a side (parallel) approach is allowed instead of knee space (§606.2 exception 1).

Does an existing counter have to be lowered?

Not if it met the 1991 Standards (for a cash register counter, a 36 inch long section no higher than 36 inches) and has not been altered since March 15, 2012: that is the safe harbor in 28 CFR 36.304(d)(2)(i). A non-compliant counter must be fixed where readily achievable under 36.304(a), and any alteration must meet the 2010 Standards under 36.406.

How deep does the lowered section of a counter have to be?

As deep as the counter top it is part of (§904.4). On a split-height counter, the Justice Department’s commentary in 28 CFR Part 36 Appendix B applies the rule only to the customer side, so the staff side can sit higher or lower. No standard sets a separate minimum depth; 24 inches appears only as an alteration length exception.

What is the ADA height for a bar?

Bars count as dining surfaces (Advisory 902.1), so at least 5% of the seating and standing spaces must be at a surface 28 to 34 inches high with knee space 27 inches high and 30 inches wide (§226.1, §902.3, §306). The older 60 inch lowered bar section came from 1991 ADAAG 5.2 and is not the 2010 rule.

Sources

Last reviewed November 2026 by the CB&C Editorial Team. See our editorial standards.

← Back to all articles