Skip to content

ADA Ramp Requirements: Every Dimension in Section 405, With a Worked Example

Concrete switchback access ramp with steel handrails leading to a glass storefront entrance

ADA ramp requirements set a running slope no steeper than 1:12, at most 30 inches of rise per run, 36 inches of clear width, 60-inch landings at both ends, and handrails on both sides once rise exceeds 6 inches.

Key takeaways

  • A ramp is any walking surface steeper than 1:20 (5%), and its runs may be no steeper than 1:12 (8.33%) with a cross slope of 1:48 or flatter (2010 ADA Standards, 106.5, 405.2, 405.3).
  • Each run may rise 30 in at most, so a 36 in rise needs two runs and three 60 in landings, about 51 ft in a straight line (Sections 405.6 and 405.7).
  • Handrails on both sides become mandatory when a run rises more than 6 in; the 1991 rule that also triggered them at 72 in of length no longer applies (1991 Standards 4.8.5).
  • The 2024 IBC lets a pedestrian ramp that is neither an exit route nor an accessible route slope 1:8, but an egress ramp serving 50 or more occupants generally needs the 44 in width of a corridor (IBC Sections 1012.2 and 1020.3).
  • Public bids priced concrete curb ramps at $1,500 to $12,615 each in 2024 and 2025, and 10 federal building-ramp contracts signed from 2022 to 2026 ran $33,225 to $228,503 (NCDOT, USAspending.gov).

What are the ADA ramp requirements?

Under the 2010 ADA Standards for Accessible Design, a ramp run may slope no more than 1 in 12, rise no more than 30 in, and must give 36 in of clear width with a level 60 in landing at the top and bottom. Runs that rise over 6 in need handrails on both sides and edge protection (Sections 405 and 505, U.S. Access Board, accessed November 2026).

The U.S. Department of Justice adopted these standards on September 15, 2010, and they are mandatory for new construction and alterations whose permit application was certified complete, or whose construction started, on or after March 15, 2012 (28 CFR 36.406(a)). Ramps are needed wherever an accessible route changes level by more than 1/2 in and no elevator or platform lift is used (Section 303.4).

Element2010 ADA requirementSectionSource
When a ramp is requiredAny change in level over 1/2 in (unless an elevator or lift is used); any walking surface steeper than 1:20 (5%)303.4, 106.5Access Board
Running slope1:12 max (8.33%), uniform along the run405.2Access Board
Cross slope1:48 max (2.08%)405.3Access Board
Clear width36 in min, measured between handrails where provided405.5Access Board
Rise per run30 in max; no limit on the number of runs405.6Access Board guide
LandingsAt top and bottom of every run; 60 in long min; as wide as the widest run; slope 1:48 max405.7.1 to 405.7.3Access Board
Turn at a landing60 in x 60 in clear min405.7.4Access Board
HandrailsBoth sides when a run rises more than 6 in; top of gripping surface 34 to 38 in405.8, 505.2, 505.4Access Board
Handrail extensions12 in min, horizontal, beyond top and bottom of each run505.10.1Access Board
Edge protection12 in extended surface beyond the handrail, or a curb or barrier that stops a 4 in sphere within 4 in of the surface405.9Access Board
SurfaceFirm, stable, slip resistant; no openings that pass a 1/2 in sphere302.1, 302.3Access Board
Exterior landingsBuilt so water does not collect405.10Access Board
Single ramp run elevation with 2010 ADA Standards dimensions Side view of one ramp run with bottom and top landings, 1:12 running slope, 30 inch maximum rise, 60 inch landings, handrails 34 to 38 inches high and 12 inch extensions. One ramp run: 2010 ADA Standards Sections 405 and 505 Rise: 30 in max per run (405.6) Run: 12 in of length for each 1 in of rise at the 1:12 maximum Bottom landing 60 in min Top landing 60 in min Running slope 1:12 max 8.33%, cross slope 1:48 max Handrails both sides if rise over 6 in Top of gripping surface 34 to 38 in (505.4) 12 in extension at bottom (505.10.1) 12 in extension at top Landing slope 1:48 max (405.7.1)
One ramp run with the 2010 ADA Standards dimensions from Sections 405.2 to 405.7 and 505.4 to 505.10.1. Source: U.S. Access Board, ADA Accessibility Standards, accessed November 2, 2026. Not to scale.

All 2010 dimensions carry normal construction tolerances unless a rule is written as a range, such as the 34 to 38 in handrail height (Section 104.1.1). The U.S. Access Board therefore recommends designing exterior ramps at 7.5% running slope and 1.5% cross slope, so that concrete placed slightly steep still lands under 8.33% and 2.08% (Access Board ramp guide).

Landings

Every run needs a landing at its top and bottom, 60 in long and at least as wide as the widest run that reaches it, sloped no more than 1:48 for drainage (Sections 405.7.1 to 405.7.3). Where a door opens onto the landing, its maneuvering clearance may overlap the 60 in landing (Section 405.7.5), though the Access Board advises keeping the door swing off the landing.

How long does a ramp have to be for a given rise?

At the 1:12 maximum, every inch of rise needs 12 in of run, so the sloped length in feet equals the rise in inches. Add a 60 in landing at each end, and one more for every extra run once rise passes 30 in. A 24 in rise needs a 24 ft run and about 34 ft in a straight line (Sections 405.2, 405.6, 405.7).

Total riseSloped length at 1:12Runs (30 in max each)Landings at 60 inStraight footprint at 1:12Straight footprint at 7.5% design slopeHandrails required?
6 in6 ft1216.0 ft16.7 ftNo (rise not over 6 in)
12 in12 ft1222.0 ft23.3 ftYes
18 in18 ft1228.0 ft30.0 ftYes
24 in24 ft1234.0 ft36.7 ftYes
30 in30 ft1240.0 ft43.3 ftYes
36 in36 ft2351.0 ft55.0 ftYes
48 in48 ft2363.0 ft68.3 ftYes
60 in60 ft2375.0 ft81.7 ftYes

The table assumes straight runs; a switchback or dogleg puts the same run length into a smaller site but needs a 60 x 60 in landing at each turn. The 7.5% column uses the Access Board’s recommended design slope. A 6 in rise is the last row without handrails, because Section 405.8 triggers them only when rise is greater than 6 in.

Straight-line ramp footprint by total riseBar chart: a straight ramp needs 16 ft for a 6 in rise, 34 ft for 24 in and 75 ft for 60 in at the 1:12 maximum.020.040.060.080.0100feet16.016.76 in22.023.312 in28.030.018 in34.036.724 in40.043.330 in51.055.036 in63.068.348 in75.081.760 inAt 1:12 (8.33%)At 7.5% design slope
A 24 in rise needs about 34 ft in a straight line at 1:12 and 36.7 ft at the Access Board’s 7.5% design slope; the jump at 36 in is the second run and third landing. CB&C calculation from 2010 ADA Standards Section 405, November 2026.

Worked example: a 24 in rise at a storefront door

A tenant space whose finished floor sits 24 in above the sidewalk needs one run, because 24 in is under the 30 in cap. The arithmetic below shows every input, from run length to handrail footage, using Sections 405 and 505 and one IBC check. The same steps apply to a retail entrance or a jobsite office trailer.

StepArithmeticResultRule
1. Runs needed24 in is not more than 30 in1 run405.6
2. Minimum run length24 in x 12288 in = 24 ft 0 in405.2
3. Design run at the Access Board’s 7.5% target24 in / 0.075320 in = 26 ft 8 inAccess Board guide
4. Landings2 landings x 60 in10 ft405.7.3
5. Straight footprint24 ft + 10 ft (or 26 ft 8 in + 10 ft)34 ft at 1:12; 36 ft 8 in at 7.5%CB&C calculation
6. Clear widthBetween handrail inside faces36 in min405.5
7. Cross slope check36 in / 480.75 in max fall across the run405.3
8. Handrails24 in is more than 6 inBoth sides, 34 to 38 in high405.8, 505.4
9. Handrail length2 x (24.08 ft sloped length + 2 x 1 ft extensions)About 52 linear feet505.10.1, CB&C calculation
10. Slab width with extended-surface edge protection36 in + 12 in + 12 in, plus rail posts60 in min of walking surface405.9.1
11. Guard check (IBC)24 in drop, level grade beside the ramp, is not more than 30 inNo 42 in guard triggeredIBC 1015.2

The two edge protection options change the slab. With a 12 in extended surface on each side, the concrete must be at least 60 in wide; with a 4 in curb or a barrier that stops a 4 in sphere, the slab can stay near 36 in plus rail posts (Section 405.9). The extended surface needs more site width; a curb or barrier suits a tight lot line. Who carries the entrance work in a ground-floor fit-out is covered in our guide to tenant improvement contractors.

When are handrails and edge protection required?

Handrails are required on both sides of any ramp run that rises more than 6 in (Sections 405.8 and 505.2), at a gripping height of 34 to 38 in, continuous along each run and extended 12 in horizontally at the top and bottom. Edge protection is required on both sides of runs and landings, with three exceptions in Section 405.9 (Access Board, 2010 Standards).

  • Height: top of the gripping surface 34 in min and 38 in max above the ramp surface, kept consistent (505.4).
  • Clearance: 1-1/2 in min between the gripping surface and a wall (505.5).
  • Shape: circular 1-1/4 to 2 in outside diameter; non-circular 4 to 6-1/4 in perimeter and 2-1/4 in max cross-section (505.7).
  • Grip: bottoms obstructed for no more than 20% of the length (505.6); rails may not rotate in their fittings (505.9).
  • Continuity: continuous along each run; inside rails on switchback and dogleg ramps continuous between runs (505.3).
  • Extensions: 12 in min beyond the top and bottom of each run, returning to a wall, guard or the landing surface, or joining the next run’s rail (505.10.1).
Ramp plan view with clear width, landings and edge protection options Plan of a straight ramp run: 36 inch minimum clear width between handrails, 60 inch landings, handrail extensions of 12 inches, edge protection by a 12 inch extended surface or a curb or barrier, and a 60 by 60 inch landing where a ramp turns. Plan view: width, landings and edge protection (405.5, 405.7, 405.9) Option A: surface extends 12 in min beyond the inside face of the handrail (405.9.1) Bottom landing 60 in long min, as wide as the run Ramp run, UP Top landing 60 in long min, slope 1:48 max Handrail runs 12 in past each end of the run (505.10.1) 36 in min clear between handrails Option B: curb or barrier that stops a 4 in sphere within 4 in of the ramp surface (405.9.2) Ramp turns at a landing: 60 in x 60 in min clear (405.7.4) Handrails, posts and edge protection may not intrude into the 60 x 60 area. Inside handrails on switchback and dogleg ramps stay continuous (505.3).
Plan view of clear width, landings and the two edge protection options in Sections 405.5, 405.7 and 405.9, with the 60 x 60 in turn landing of 405.7.4. Source: U.S. Access Board, ADA Accessibility Standards, accessed November 2, 2026.

Edge protection is waived on ramps that need no handrails and have side flares no steeper than 1:10, on landing sides that serve an adjoining run or stair, and on landing sides with a drop of 1/2 in or less within 10 in of the minimum landing area (405.9 exceptions 1 to 3). The Standards set a 36 in minimum between handrails but no maximum, and they require no center rail on a wide ramp (Access Board guide).

How are curb ramps (Section 406) different from ramps (Section 405)?

A curb ramp is a short ramp that cuts through a curb or is built up to it. It keeps the 1:12 running slope, 1:48 cross slope and 36 in width of a ramp, but needs only a 36 in top landing, no handrails and no edge protection, and adds limits on side flares (1:10) and gutter counter slope (1:20) under Sections 406.1 to 406.4 (Access Board, 2010 Standards).

ItemRamp (405)Curb ramp (406)
Running slope1:12 max1:12 max (406.1 applies 405.2)
Cross slope1:48 max1:48 max (405.3)
Clear width36 in min36 in min, excluding flares (405.5)
Rise per run30 in maxNot applied (406.1 does not reference 405.6)
LandingsTop and bottom of each run, 60 in longTop only, 36 in long min (406.4)
HandrailsBoth sides above 6 in of riseNot required
Edge protectionRequired (405.9)Not specified
Side flaresNot applicable1:10 max; 1:12 max in alterations with no top landing (406.3, 406.4)
Counter slope of gutter and roadNot applicable1:20 max (406.2)
LocationOn the accessible routeNot into traffic lanes, parking spaces or access aisles (406.5)
Detectable warningsNot requiredOnly at DOT-covered transit facilities and FHWA-funded projects

Detectable warnings, the truncated-dome pads, are required on curb ramps only at transit facilities covered by the U.S. Department of Transportation’s ADA standards and on projects funded by the Federal Highway Administration; other sites covered by the Department of Justice standards do not need them (Access Board guide). City sidewalk contracts can still include them: Tampa’s August 2026 sidewalk bid carried a 350 SF detectable warning line.

Where do the IBC, ICC A117.1 and state codes differ from the ADA?

Local building departments enforce the International Building Code (IBC), which repeats most ADA ramp numbers in Section 1012 and points to ICC A117.1 for accessible routes. The IBC is stricter on width, doors and guards, and looser for ramps that are neither exits nor accessible routes, which may slope 1:8. California’s Chapter 11B is stricter again (ICC, IBC 2024 Chapter 10).

Item2010 ADA Standards2024 IBC Section 1012California CBC Chapter 11B (2025)Source
Max slope1:12 on accessible routes1:12 for egress ramps; 1:8 (12.5%) for other pedestrian ramps (1012.2)1:12 (11B-405.2)IBC 2024, CA BSC
Rise per run30 in30 in (1012.4)30 in (11B-405.6)Tip Sheet 13
Clear width36 in36 in between handrails, and not less than the corridor width in Table 1020.3: 44 in in most buildings, 36 in under 50 occupants (1012.5.1)48 in; 36 in for some residential ramps serving 50 or fewer (11B-405.5)IBC 2024, CA BSC
Landing length60 in60 in; 48 in is enough off the accessible route; 36 in in non-accessible R-2 and R-3 units (1012.6.3)60 in; bottom landing 72 in (11B-405.7.3)IBC 2024, CA BSC
Turn landing60 x 60 in60 x 60 in (1012.6.4)60 x 72 in (11B-405.7.4)CA BSC
HandrailsRise over 6 in, both sidesRise over 6 in, both sides (1012.8, 1014)On ramp runs, curb ramps excepted (11B-405.8)Tip Sheet 13
Headroom80 in vertical clearance (307.4)80 in over ramp and landings (1012.5.2)Follows CBCDOJ, IBC 2024
Doors at landingsManeuvering space may overlap the landing (405.7.5)A door swing may not cut landing width below 42 in (1012.5.3)Follows 11BIBC 2024
Edge curbStops a 4 in sphere within 4 in of the surfaceCurb 4 in min, or barrier that stops a 4 in sphere (1012.10.1)Barrier stops a 4 in sphere (11B-405.9.2)Tip Sheet 13
GuardsNot in Section 40542 in guard where the drop exceeds 30 in within 36 in of the edge (1015.2, 1015.3)Follows CBCTip Sheet 13

A Washington tip sheet written for the 2021 IBC and ICC A117.1-2017 cites the same 1:12 slope, 30 in rise, 1:48 cross slope, 34 to 38 in handrail height and 12 in extensions to both documents, and it shows a state amendment that sets 48 in width for exterior ramps (MyBuildingPermit.com Tip Sheet 13, March 2024). Where the ADA and the local code differ, the design has to meet both, so the stricter number wins on each line. Your building department applies the IBC edition your state adopted, and what that plan review asks for is listed on our page about commercial building permits.

This page summarizes the 2010 ADA Standards and model codes and is not legal advice; the building official who issues your permit and the federal agencies that enforce the ADA decide compliance on a given site.

What do many ramp guides still get wrong?

Several ranking ramp guides still repeat 1991 rules or borrow building-code guard rules and label them ADA. The 1991 ADA Standards triggered handrails at 72 in of ramp length and set a 2 in curb; the 2010 Standards dropped both, and neither version requires balusters (1991 ADA Standards, Section 4.8). The table compares four claims with the primary text.

What some ramp guides sayWhat the primary source saysSource
Handrails are required when rise exceeds 6 in or the ramp is longer than 72 in (guide updated January 2026)The 72 in length trigger was 1991 rule 4.8.5. The 2010 rule (405.8) uses rise only: over 6 in.1991 Standards, 2010 Standards
Edge curbs must be at least 2 in high (same guide)2 in was 1991 rule 4.8.7. Section 405.9.2 now uses a 4 in sphere test; the Access Board reads a curb as 4 in min.1991 Standards, Access Board guide
A ramp run may be no longer than 30 ft (vendor guide dated 2017)Section 405.6 limits rise per run to 30 in. A run is 30 ft only at exactly 1:12; a flatter run can be longer.2010 Standards
Balusters 4 in apart and a 42 in guardrail are ADA ramp rules (same 2017 guide)Neither appears in 405 or 505. A 42 in guard comes from IBC 1015 where a drop exceeds 30 in.Tip Sheet 13

The 1991 rules still matter in one case: a private owner whose path-of-travel ramp was built to the 1991 Standards does not have to retrofit it to the 2010 changes solely because a primary function area it serves is altered (28 CFR 36.403(a)(2)). The 1991 cross slope limit was 1:50; the 2010 limit is 1:48 (Section 405.3).

Which ramp rule applies to your project?

Start with the size of the level change, then ask whether the ramp crosses a curb, whether the building is existing and space-limited, and how much it rises. Those four answers set the slope, the landing count, and whether handrails and edge protection apply. The table gives each threshold with its section; the flowchart shows the same order (2010 Standards, Sections 303, 405, 406).

IfThenRule
The change in level is 1/4 in or lessIt may be vertical; no ramp303.2
The change is over 1/4 in up to 1/2 inBevel it at 1:2 or flatter303.3
The change is over 1/2 inRamp, curb ramp, elevator or platform lift303.4, 402.2
A walking surface is 1:20 (5%) or flatterNot a ramp; no handrails required403.3, 505.1 advisory
A run rises more than 6 inHandrails on both sides plus edge protection405.8, 405.9
A run rises 6 in or less and its sides flare at 1:10 or flatterNo handrails and no edge protection required405.9 exception 1
Total rise exceeds 30 inSplit into runs with a 60 in landing between them405.6, 405.7
The ramp turns at a landing60 x 60 in clear landing405.7.4
Existing building, no room for 1:12, rise 6 in or lessSlope up to 1:10 allowedTable 405.2
Existing building, no room for 1:12, rise 3 in or lessSlope up to 1:8 allowedTable 405.2
The ramp cuts through a curbCurb ramp rules: 36 in top landing, flares 1:10406
An alteration affects a primary function areaPath of travel, ramps included, up to 20% of the alteration cost28 CFR 36.403(f)
The project is in California48 in width, 72 in bottom landing, handrails on ramp runsCBC 11B-405
A drop over 30 in sits within 36 in of the ramp edge42 in guard under the IBCIBC 1015.2, 1015.3
Which ADA ramp rule applies: decision flowchart Flowchart from change in level to curb ramp, existing building slope exceptions, handrail trigger at 6 inches of rise and extra runs above 30 inches of rise. Which ramp rule applies? (2010 ADA Standards) Change in level over 1/2 in, or a walking slope steeper than 1:20? No Not a ramp: 1/4 in vertical or 1/2 in bevel at 1:2 (303) Yes Does it cut through or build up to a curb? Yes Curb ramp (406): 1:12, 36 in wide, 36 in top landing, flares 1:10, no handrails required No Existing building where space rules out a 1:12 slope? Yes Table 405.2: up to 1:10 for 6 in rise max; up to 1:8 for 3 in rise max; never steeper than 1:8 No Ramp (405): slope 1:12 max, cross slope 1:48 max, 36 in clear width, 60 in landings top and bottom Is the rise of a run over 6 in? No Handrails not required; edge protection still due unless sides flare at 1:10 max Yes Handrails both sides, 34 to 38 in high, 12 in extensions (505), plus edge protection (405.9) Is the total rise over 30 in? No One run with a landing at each end Yes Split into runs of 30 in rise max, a 60 in landing between runs, 60 x 60 in where the ramp turns State codes can be stricter: California 11B requires 48 in width and handrails on ramp runs. Section numbers refer to the 2010 ADA Standards for Accessible Design.
Decision path for ramp rules under the 2010 ADA Standards Sections 303, 405, 406 and Table 405.2, with the California 11B width note. Source: U.S. Access Board and California Building Standards Commission, accessed November 2, 2026.

In alterations, the 20% rule sets how far the owner must go: when a primary function area is altered, spending on an accessible path of travel, ramps included, is required up to 20% of the alteration cost before it counts as disproportionate (28 CFR 36.403(f)). The calculation for a tenant floor is worked through in our office renovation guide.

How do you measure an existing ramp?

A field check needs a digital level, a tape and a 4 in ball or gauge. Measure total rise first, because it decides the number of runs (30 in each) and whether handrails apply (over 6 in). Then check slope, width, landings, rails and edges against Sections 302 to 505 (Access Board guide), logging each reading on the construction punch list.

  1. Total rise: measure from bottom landing to top landing surface. Over 30 in means more than one run; over 6 in means handrails (405.6, 405.8).
  2. Running slope: read the level at several points on each run; 8.33% max, with no grade breaks inside a run (405.2, 405.4). On a 24 in level, 1:12 equals a 2 in rise.
  3. Cross slope: 2.08% max across runs and landings, which is 0.75 in over 36 in (405.3, 405.7.1).
  4. Clear width: 36 in min between the inside faces of the handrails (405.5).
  5. Landings: 60 in clear length at top and bottom of every run, as wide as the run; 60 x 60 in where the ramp turns, with no post or rail inside that square (405.7).
  6. Handrails: both sides, 34 to 38 in to the top of the gripping surface, 1-1/2 in clearance, 1-1/4 to 2 in round profile, 12 in extensions at top and bottom (505.4 to 505.10).
  7. Edge protection: a 12 in extended surface beyond the handrail, or a curb or barrier the 4 in ball cannot pass within 4 in of the surface (405.9).
  8. Surface and joints: firm, stable, slip resistant; gaps that pass no more than a 1/2 in sphere; level changes at the ends of 1/4 in vertical or up to 1/2 in beveled at 1:2 (302, 303).
  9. Drainage and headroom: exterior landings shed water (405.10); 80 in min vertical clearance along the route (307.4).

Photograph each reading so a run steeper than 8.33% or a landing shorter than 60 in is caught before the certificate of occupancy inspection. Under Section 104.1.1, field tolerances apply to fixed dimensions such as 1:12 but not to ranges such as 34 to 38 in.

What does an ADA ramp cost?

Public records give two price levels. Concrete curb ramps bid at $1,500 to $2,000 each in Fort Thomas, Kentucky (May 2025), $2,800 to $3,277.50 in Randolph County, North Carolina (December 2024) and $5,931.10 to $12,615 in Rancho Santa Margarita, California (September 2024). Ten federal building-ramp contracts signed from 2022 to 2026 cost $33,225 to $228,503, a median of $85,778 (NCDOT bid tabulation, USAspending.gov).

Item (scope)Place and bid dateUnit prices bidSource
Remove and construct concrete curb ramp, Caltrans Standard Plan A88A (17 ramps)Rancho Santa Margarita, CA; Sep 24, 2024$5,931.10 to $12,615.00 per ramp (5 bidders)City bid tabulation
New concrete curb ramp (11 ramps); remove and replace curb ramp (94 ramps)Randolph County, NC (NCDOT); Dec 10, 2024$2,800.00 to $3,277.50 per ramp (3 bidders)NCDOT bid tabulation
ADA curb ramp (2 ramps)Fort Thomas, KY; May 21, 2025$1,500 to $2,000 per ramp (4 bidders; engineer estimate $1,000)City bid tabulation
Aluminum handrail, FDOT Index 870 two-rail (20 LF)Tampa, FL; Aug 18, 2026$85 to $300 per linear foot (4 bidders)City of Tampa bid tabulation
4 in concrete sidewalk (1,400 SY)Tampa, FL; Aug 18, 2026$72.00 to $85.00 per square yardCity of Tampa bid tabulation
Detectable warnings (350 SF)Tampa, FL; Aug 18, 2026$25 to $46 per square footCity of Tampa bid tabulation

The curb ramp spread runs about 3 to 8 times between the Kentucky and California bids, and the California contract paid separately for water pollution control, traffic control and mobilization. Handrail shows the widest spread of the component prices: Tampa’s four bids for the same 20 LF of two-rail aluminum ranged from $85 to $300 per foot. For the 24 in worked example, about 52 LF of handrail at those prices is $4,420 to $15,600 before concrete, landings and demolition (CB&C calculation).

Federal contract (building ramp)PlaceSignedAward amountSource
New ADA ramp at Building 2911Fort Bliss, TXSep 2022$228,503USAspending.gov
Construct ADA rampLangley AFB, VAAug 2025$175,230USAspending.gov
Install ADA rampFort Leavenworth, KSJul 2025$147,747USAspending.gov
Install pre-engineered ADA ramp (12 offers)Concord, CAJul 2024$127,000USAspending.gov
ADA ramp at Building 516Fort Bliss, TXSep 2022$90,908USAspending.gov
Demolish and install ADA ramp (4 offers)Mescalero, NMAug 2026$80,648USAspending.gov
Building 40 emergency ADA rampFort Defiance, AZMay 2026$70,581USAspending.gov
Wheelchair ramp, Building 512, VA medical centerRichmond, VASep 2022$62,594USAspending.gov
ADA ramp and crosswalk, VA medical centerDallas, TXFeb 2026$43,315USAspending.gov
Install accessible ramp, national parkAlamogordo, NMJun 2024$33,225USAspending.gov
Federal ADA ramp contracts, 2022 to 2026Horizontal bar chart: 10 federal ADA ramp contracts from $33,225 in New Mexico to $228,503 at Fort Bliss, Texas; median $85,778.$New ADA ramp at Building 2911, Fort Bliss,228,503Construct ADA ramp, Langley AFB, VA (Aug 2175,230Install ADA ramp, Fort Leavenworth, KS (Ju147,747Install pre-engineered ADA ramp (12 offers127,000ADA ramp at Building 516, Fort Bliss, TX (90,908Demolish and install ADA ramp (4 offers), 80,648Building 40 emergency ADA ramp, Fort Defia70,581Wheelchair ramp, Building 512, VA medical 62,594ADA ramp and crosswalk, VA medical center,43,315Install accessible ramp, national park, Al33,225
Ten federal building-ramp contracts signed from September 2022 to August 2026 ranged from $33,225 to $228,503, a median of $85,778. Source: USAspending.gov award records, pulled November 2, 2026.

Federal construction awards carry Davis-Bacon wage rules and federal contract terms, and the records do not state ramp size, so they show what a whole ramp contract costs rather than a unit price. Modular ramp purchases in the same records ran $14,952 for a U.S. Coast Guard ramp in New York (2023), $16,606 in Tennessee (2026) and $17,919 for a custom residential unit in Michigan (2022). What to normalize before comparing ramp quotes is listed in our guide to comparing construction bids.

Ramps usually lead to an accessible entrance, so the door rules in our ADA door width guide apply at the top landing, and the route from the lot starts in our ADA parking requirements guide.

Guard heights, OSHA rail numbers and a field checklist for the same rails are in our guide to commercial handrail height.

Where a level change is taken by steps instead of a ramp, the 4 to 7 in riser and 11 in tread limits are in our guide to commercial stair riser height.

How we compiled this

We read the 2010 and 1991 ADA Standards, the Access Board’s ramp guide, IBC 2024 Section 1012 and Table 1020.3 (via the 2025 California Building Code, as the ICC viewer blocked automated reads) and a 2021 IBC and A117.1-2017 tip sheet, all in November 2026. Prices come from 4 public bid tabulations and 13 USAspending.gov awards. We could not open ICC A117.1-2017 itself, so A117.1 rows rely on the tip sheet.

Frequently asked questions

What is the maximum slope for an ADA ramp?

The maximum running slope is 1:12, or 8.33%, which means 12 in of run for each inch of rise, and the cross slope may not exceed 1:48 (Sections 405.2 and 405.3 of the 2010 ADA Standards). Only existing buildings without room for 1:12 may go steeper: up to 1:10 for a rise of 6 in or less, and up to 1:8 for 3 in or less.

How long does a ramp need to be for a 24 inch rise?

A 24 in rise needs at least 24 ft of sloped run at 1:12 and a 60 in landing at the top and bottom, about 34 ft in a straight line. The U.S. Access Board recommends designing at 7.5%, which stretches the run to 26 ft 8 in and the straight footprint to 36 ft 8 in. One run is enough because 24 in is under the 30 in cap.

Do ADA ramps need handrails on both sides?

Yes, when a ramp run rises more than 6 in. Sections 405.8 and 505.2 of the 2010 ADA Standards then require handrails on both sides, 34 to 38 in high, with 12 in horizontal extensions at the top and bottom. Runs rising 6 in or less need no handrails, and curb ramps never need them.

How often does an ADA ramp need a landing?

Every run needs a landing at its top and bottom, and a run may rise no more than 30 in, so a level 60 in landing is needed at least every 30 in of rise, which is every 30 ft of run at 1:12. Where the ramp changes direction, the landing must be 60 x 60 in clear (Sections 405.6 and 405.7, Access Board).

Do curb ramps need detectable warnings?

Under the Department of Justice’s 2010 Standards, curb ramps at ordinary sites do not need detectable warnings. They are required on curb ramps at transit facilities covered by the U.S. Department of Transportation’s ADA standards and on projects funded by the Federal Highway Administration, according to the U.S. Access Board guide. City sidewalk contracts can still include them, such as Tampa’s August 2026 bid.

Can a portable or temporary ramp meet the ADA?

Only in narrow cases. The U.S. Access Board says required ramps and curb ramps must be permanent and installed at the time of construction or alteration. Portable ramps are allowed for temporary structures, and ramps to raised courtroom work stations may be added later if space for them was designed in. A permanent ramp still has to meet Section 405.

Sources

Last reviewed November 2026 by the CB&C Editorial Team. See our editorial standards.

← Back to all articles