Commercial stair riser height must be 4 to 7 inches under IBC Section 1011.5.2, with treads at least 11 inches deep and no more than 3/8 inch of variation in any flight.
Key takeaways
- The 2024 International Building Code (IBC) caps a commercial stair riser at 7 in and sets a 4 in floor, measured vertically between the nosings of adjacent treads (IBC Section 1011.5.2).
- Within one flight, the tallest riser may exceed the shortest by 3/8 in at most, and the same 3/8 in limit applies to tread depth (IBC Section 1011.5.4).
- Houses built under the International Residential Code (IRC) may use a 7 3/4 in riser and 10 in tread, so a residential stair is not a legal model for an office or retail stair (IRC R311.7.5, City of Boise handout, 2022).
- OSHA 29 CFR 1910.25 lets a workplace stair rise 9.5 in per step at 30 to 50 degrees, but where the building code also applies, the 7 in IBC limit governs (OSHA 1910.25(c)).
- A 13 ft 4 in (160 in) floor-to-floor height needs 23 risers of about 6.96 in, 21 treads of 11 in and an intermediate landing, because one flight may rise 12 ft at most (IBC Section 1011.8).
What is the maximum stair riser height for commercial stairs?
For a commercial building, the maximum stair riser height is 7 inches and the minimum is 4 inches under 2024 IBC Section 1011.5.2. Rectangular treads must be at least 11 inches deep, measured horizontally from nosing to nosing. These limits apply to every stairway serving an occupied part of the building, whether or not it is an exit, unless an exception in Section 1011 applies.
The IBC is the model code that nearly every US state adopts for commercial construction, often with local amendments. Which IBC group your building falls into (business, mercantile, assembly, storage) decides which stair exceptions are open to you; our guide to IBC occupancy classification lists the groups and their triggers.
| Dimension | Commercial limit | IBC 2024 section | Source |
|---|---|---|---|
| Riser height | 4 in min, 7 in max | 1011.5.2 | ICC; Humboldt County, NV |
| Tread depth (rectangular) | 11 in min | 1011.5.2 | ICC |
| Variation within a flight | 3/8 in max, risers and treads | 1011.5.4 | ICC |
| Nosing projection | 1 1/4 in max | 1011.5.5.1 | NYC 2022 BC |
| Nosing radius or bevel | 1/16 in to 9/16 in | 1011.5.5 | NYC 2022 BC |
| Stair width | 44 in min; 36 in for 50 or fewer occupants | 1011.2 | Humboldt County, NV |
| Headroom | 80 in min above the nosing line | 1011.3 | Humboldt County, NV |
| Landing depth | Equal to stair width; 48 in max required on a straight run | 1011.6 | Humboldt County, NV |
| Rise of one flight | 12 ft max between landings | 1011.8 | Humboldt County, NV |
| Tread and landing slope | 1:48 (2%) max | 1011.7.1 | NYC 2022 BC |
Handrails (34 to 38 in above the nosings under IBC Section 1014) and guards (42 in under Section 1015) are separate rules with their own dimensions, and this page does not repeat them.
How do IBC, IRC, OSHA and ADA stair rules compare?
Four rule sets reach commercial and mixed-use stairs, and they disagree on riser height by up to 2.5 inches. The IBC and the 2010 ADA Standards both allow 4 to 7 in risers with 11 in treads. The IRC allows 7 3/4 in risers in houses. OSHA 1910.25 allows 9.5 in risers for workplace stairs. When two rules apply to the same stair, build to the stricter number.
| Rule set | Covers | Max riser | Min tread | Uniformity | Min width | Headroom | Source |
|---|---|---|---|---|---|---|---|
| IBC 2024 Section 1011 | Stairs in commercial, institutional and multifamily buildings | 7 in (4 in min) | 11 in | 3/8 in per flight | 44 in (36 in at 50 or fewer occupants) | 80 in | ICC IBC 2024 |
| 2010 ADA Standards 504 | Stairs on a required means of egress in public accommodations and commercial facilities | 7 in (4 in min) | 11 in | Uniform risers and treads | Not set; building code governs | Not set | U.S. Access Board |
| IRC 2024 R311.7 (contrast only) | One- and two-family houses and townhouses | 7 3/4 in | 10 in | 3/8 in per flight | 36 in | 6 ft 8 in | City of Boise; ICC IRC 2024 |
| OSHA 29 CFR 1910.25(c) | Standard stairs in general-industry workplaces | 9.5 in | 9.5 in | Uniform between landings | 22 in | 6 ft 8 in | OSHA |
| OSHA 29 CFR 1926.1052 | Temporary stairs during construction | Not set (30 to 50 degrees) | Not set | 1/4 in in any stairway system | 22 in at landings | Not set | OSHA |
Where does the ADA add to the IBC?
The ADA’s numbers for risers and treads match the IBC, so the ADA mostly adds restrictions on shape. Section 504.3 bans open risers, Section 504.5 limits the nosing radius to 1/2 in and lets the riser slope back no more than 30 degrees, and Section 210.1 applies all of this only to stairs that form part of a required means of egress (2010 ADA Standards).
The ADA allows a nosing projection of 1 1/2 in, but IBC Section 1011.5.5.1 caps it at 1 1/4 in. A guide that quotes only the ADA figure leaves a stair 1/4 in out of compliance in any IBC jurisdiction. The same logic applies to ramps; the slope and landing rules for those sit in our guide to ADA ramp requirements.
How do you calculate riser height and tread count for a floor-to-floor height?
Divide the floor-to-floor height by 7 inches and round up to get the minimum number of risers, then divide the height by that count to get the actual riser height. The tread count is one fewer than the riser count in each flight. If the total rise exceeds 144 inches (12 ft), IBC Section 1011.8 requires an intermediate landing.
- Measure finished floor to finished floor, including the topping, tile or carpet pad that will be installed. Section 1011.5.1 excludes carpets, rugs and runners from the reference surface.
- Divide the height by 7 in and round up: 160 in / 7 in = 22.86, so 23 risers minimum.
- Divide the height by the riser count: 160 in / 23 = 6.957 in per riser.
- Check the 4 in minimum and the 3/8 in tolerance. If you round risers to 1/16 in for fabrication, mix two sizes no more than 1/16 in apart so the total still equals the floor-to-floor height.
- Split into flights of 144 in or less: 12 risers (83.5 in) and 11 risers (76.5 in).
- Count treads per flight (risers minus 1) and multiply by 11 in or more: 11 + 10 = 21 treads, 231 in of tread run.
- Add landings at least as deep as the stair width: a 44 in stair needs a 44 in intermediate landing plus full landings at top and bottom.
- Check headroom: 80 in clear above the line connecting the nosings, along the full stair and landing width.
| Step | Input | Arithmetic | Result | Rule |
|---|---|---|---|---|
| Floor-to-floor height | 13 ft 4 in | 13 x 12 + 4 | 160 in | 1011.5.1 |
| Minimum risers | 7 in max riser | 160 / 7 = 22.86, round up | 23 risers | 1011.5.2 |
| Actual riser | 23 risers | 160 / 23 | 6.957 in | 1011.5.2 |
| Fabrication sizes | 1/16 in increments | 16 x 6 15/16 in + 7 x 7 in = 111 + 49 | 160 in, spread 1/16 in | 1011.5.4 |
| Flights | 144 in max per flight | 12 x 6.957 and 11 x 6.957 | 83.5 in and 76.5 in | 1011.8 |
| Treads | 11 in min | (11 + 10) x 11 in | 231 in (19 ft 3 in) | 1011.5.2 |
| Straight-run length | 44 in landing | 231 + 44 | 275 in (22 ft 11 in) between end landings | 1011.6 |
| Switchback stairwell length | Longer flight plus landing | 11 x 11 + 44 | 165 in (13 ft 9 in) | 1011.6 |
| Pitch | 6.957 in rise, 11 in run | arctan(6.957 / 11) | 32.3 degrees | Check only |
Adding a 24th riser drops each step to 6.667 in and lengthens the run by one 11 in tread. IBC Section 1011.5.2 sets no rise-plus-run formula for commercial stairs; New York City’s 2022 Building Code applies a 24 to 25 1/2 in “two risers plus one tread” rule only to its Group R-2 exception (NYC 2022 BC 1011.5.2, Exception 3.1).
How wide must a commercial stair be, and how much headroom does it need?
A commercial stair must be at least 44 inches wide, or 36 inches if it serves 50 or fewer occupants cumulative for all stories, under IBC Section 1011.2. Above that floor, width comes from occupant load: IBC Section 1005.3.1 multiplies the occupants of the largest story by 0.3 inch each. Headroom is 80 inches minimum, measured vertically from the line of nosings.
| Occupant load of the story | Capacity at 0.3 in per occupant | Two stairs at code minimum | What governs | Source |
|---|---|---|---|---|
| 50 or fewer (all stories) | 15 in or less | 36 in each | 36 in minimum width | IBC 1011.2 Ex. 1.1 (NYC text) |
| 100 | 30 in | 44 in each | 44 in minimum width | IBC 1005.3.1, 1011.2 |
| 200 | 60 in total | 44 in each = 88 in | 44 in minimum width | IBC 1005.3.1 |
| 400 | 120 in total | 60 in each | Occupant load | IBC 1005.3.1 |
The model IBC also allows 0.2 inch per occupant in buildings with automatic sprinklers throughout and an emergency voice/alarm communication system, other than Groups H and I-2 (2024 IBC Section 1005.3.1, Exception 2, ICC). At 400 occupants that cuts required capacity from 120 in to 80 in, so two 44 in stairs would satisfy it. Ask your architect which factor the permit set uses.
A stair that is part of an accessible means of egress needs 48 in clear between handrails under IBC Section 1009.3, unless the building is fully sprinklered and the exception adopted locally removes that width. Landings must be as wide as the stair, and a door swinging onto a landing may project no more than 7 in into it when fully open (IBC 1011.6, Humboldt County handout).
Which stair code governs your project?
The building code your jurisdiction adopted governs first: IBC Section 1011 for commercial, institutional and most multifamily buildings, and the IRC only for houses and townhouses. The ADA adds shape rules for required egress stairs in public and commercial facilities, and OSHA adds a workplace floor. Temporary construction stairs fall under OSHA 1926.1052 until the permanent stair is in.
| If the stair is | Then build to | Riser and tread | Rule |
|---|---|---|---|
| Temporary, used only during construction | OSHA construction stairway rules | 30 to 50 degrees; 1/4 in max variation; 30 in landings every 12 ft | 29 CFR 1926.1052(a) |
| Inside a dwelling unit (house, townhouse, R-2 apartment) | IRC or the IBC dwelling-unit exception | 7 3/4 in max riser, 10 in min tread | IRC R311.7.5 |
| A spiral stair from a space of 250 sq ft or less with 5 or fewer occupants | IBC spiral stair rule | 9 1/2 in max riser; 7 1/2 in tread at 12 in from the narrow edge; 26 in width | IBC 1011.10 |
| Any other stair in a commercial building | IBC Section 1011 | 4 to 7 in riser, 11 in tread, 3/8 in tolerance | IBC 1011.5.2 |
| A required egress stair in a store, office, restaurant or other public or commercial facility | IBC 1011 plus ADA 504 | Same numbers; no open risers; 1 1/4 in nosing max | ADA 210.1, 504 |
| A workplace stair to a platform or mezzanine | IBC 1011 where it applies, plus OSHA 1910.25 | 7 in under the IBC; OSHA alone allows 9.5 in | 29 CFR 1910.25(c) |
Local amendments can be stricter than the model code. New York City’s 2022 Building Code, for example, raises commercial stair headroom from 80 in to 84 in in Section 1011.3 (NYC Department of Buildings). Check the adopted edition on your permit application before the stair shop drawings go out; our guide to construction submittals covers how those drawings get reviewed.
What tolerances do inspectors check on a finished stair?
Inspectors measure the tallest and shortest riser, and the deepest and shallowest tread, in each flight. The difference may not exceed 3/8 inch under IBC Section 1011.5.4, and no riser may exceed 7 inches or fall below 4 inches. They also check nosing projection, tread slope, headroom and landing depth, usually at the final inspection before a certificate of occupancy.
| Check | Pass | Typical cause of a fail | Rule |
|---|---|---|---|
| Riser spread in one flight | 3/8 in or less | Different finish thickness at landings than on treads | IBC 1011.5.4 |
| Top or bottom riser | 4 to 7 in | Topping slab or tile added after the stair was set | IBC 1011.5.2 |
| Bottom riser at a sloped walk or drive | May drop below 4 in if the slope is 1:12 or flatter and the nosing has a 1 to 2 in marking stripe | No contrasting stripe on the short riser | IBC 1011.5.4, Ex. 3 |
| Nosing projection | 1 1/4 in max, uniform including the floor at the top | Mixed tread products in one flight | IBC 1011.5.5.1, 1011.5.5.2 |
| Tread and landing slope | 1:48 (2%) max in any direction | Exterior stairs pitched too steeply for drainage | IBC 1011.7.1 |
| Openings in treads | Pass no 1/2 in sphere; 1 1/8 in in non-public F, H and S areas | Bar grating treads in public areas | IBC 1011.7.1 |
| Solid risers | Required; perforations 1/4 in max count as solid | Open risers on an exit stair | IBC 1011.5.5.3 |
A worked failure: a steel pan stair built with uniform 6 3/4 in risers gets 1/4 in rubber tread covers on each tread, but 3/4 in of tile and mortar bed on the top landing. The top riser grows to 6 3/4 + 3/4 – 1/4 = 7 1/4 in, which breaks both the 7 in maximum and the 3/8 in spread (7 1/4 – 6 3/4 = 1/2 in). Writing finish thicknesses into the construction documents prevents it.
Fixing a poured concrete stair after the fact usually means grinding or topping each tread, so put a riser check on the construction punch list before finishes go down, not after. A failed stair can hold up the certificate of occupancy for the whole floor it serves.
When are open risers, steep nosings and spiral stairs allowed?
Open risers are banned on exit stairs and on stairs serving an accessible means of egress, but IBC Section 1011.5.5.3 allows them on other stairs if a 4 inch sphere cannot pass between treads. Group F, H and S areas closed to the public may use open risers of any size. Spiral stairs may serve as egress only from 250 square feet or less with 5 or fewer occupants.
- Open risers: allowed on non-exit stairs when the gap passes no 4 in sphere; never on a required egress stair in an ADA-covered facility (ADA 504.3).
- Nosings: curvature or bevel of 1/16 in to 9/16 in; risers vertical or sloped back no more than 30 degrees (IBC 1011.5.5).
- Winders: not allowed in means of egress stairs outside a dwelling unit, except curved and spiral stairs (IBC 1011.5.3).
- Spiral stairs: 9 1/2 in max riser, 7 1/2 in min tread at 12 in from the narrow edge, 26 in min width, 78 in headroom (IBC 1011.10).
- Alternating tread devices: 9 1/2 in max riser, limited to mezzanines of 250 sq ft or less with 5 or fewer occupants in Groups F, H and S, and to roof access (IBC 1011.14).
Need a builder who details stairs to these numbers? Request matched commercial builders and include your floor-to-floor heights and occupant loads in the brief.
Handrail and guard heights for the same stair are covered in our handrail height guide.
The occupant load that sets stair width is calculated with the factors in our occupant load factor guide.
How we compiled this
We compiled this from 9 primary documents accessed in November 2026: the 2024 IBC and IRC as published by the International Code Council, two government-published code texts based on the IBC (Humboldt County, Nevada’s IBC 2018 stair handout and New York City’s 2022 Building Code, Chapter 10), the City of Boise’s IRC handout, OSHA 29 CFR 1910.25 and 1926.1052, and the U.S. Access Board’s 2010 ADA Standards and guide. ICC’s online reader blocked automated reading, so section wording was checked against the government texts, and New York City amendments are labelled where they differ from the model code. The worked example is our own arithmetic.
Frequently asked questions
What is the maximum riser height for commercial stairs?
Under 2024 IBC Section 1011.5.2, a commercial stair riser may be no taller than 7 inches and no shorter than 4 inches, measured vertically between the nosings of adjacent treads. Treads must be at least 11 inches deep, and within one flight the largest and smallest riser may differ by 3/8 inch at most. Local amendments can be stricter, so confirm the adopted edition with your building department (ICC).
Is 7 3/4 inches a legal stair riser height?
Only in houses and dwelling units. IRC Section R311.7.5.1 allows a 7 3/4 inch riser with a 10 inch tread in one- and two-family homes and townhouses, and the IBC carries a similar exception inside dwelling units. A stair in an office, store, restaurant or other commercial space is limited to 7 inches under IBC Section 1011.5.2 (City of Boise IRC handout).
How many steps do I need for a 10 foot floor-to-floor height?
A 10 ft rise is 120 inches. Dividing 120 by the 7 inch IBC maximum gives 17.14, so round up to 18 risers of 6.67 inches each. That flight has 17 treads, and at 11 inches each the treads run 187 inches, or 15 ft 7 in. Because 120 inches is under the 144 inch flight limit in IBC Section 1011.8, no intermediate landing is required.
What is the OSHA maximum stair riser height?
OSHA 29 CFR 1910.25(c)(2) allows a standard workplace stair riser of up to 9.5 inches, with treads at least 9.5 inches deep, a width of at least 22 inches and a slope of 30 to 50 degrees. Spiral stairs also allow 9.5 inches. OSHA sets a federal workplace floor; where the building code also applies, its 7 inch limit is the one a stair must meet (OSHA).
Does the ADA require a specific stair riser height?
Yes. Section 504.2 of the 2010 ADA Standards requires uniform risers of 4 to 7 inches and treads of at least 11 inches on stairs that are part of a required means of egress. Section 504.3 bans open risers, and Section 504.5 limits the nosing radius to 1/2 inch with a projection of no more than 1 1/2 inches (U.S. Access Board).
How much can stair risers vary within a flight?
IBC Section 1011.5.4 limits the difference between the tallest and shortest riser in any flight to 3/8 inch, and applies the same limit to tread depth. OSHA 1926.1052 is tighter for temporary construction stairs: 1/4 inch in any stairway system. The common failure is a top or bottom riser that changes when a finish floor is added after the stair is built (OSHA 1926.1052).
Sources
- International Code Council, 2024 International Building Code, Chapter 10 Means of Egress, accessed 2026-11-08.
- International Code Council, 2024 International Residential Code, Chapter 3 Building Planning, accessed 2026-11-08.
- Humboldt County and City of Winnemucca Building Departments, Stairway and Landing Requirements for Commercial Buildings (IBC 2018), accessed 2026-11-08.
- NYC Department of Buildings, 2022 Building Code, Chapter 10 Means of Egress, accessed 2026-11-08.
- City of Boise, IRC Code Handout #437, Stair Treads and Risers (February 2022), accessed 2026-11-08.
- OSHA, 29 CFR 1910.25 Stairways, accessed 2026-11-08.
- OSHA, 29 CFR 1926.1052 Stairways (construction), accessed 2026-11-08.
- U.S. Access Board, 2010 ADA Standards for Accessible Design, accessed 2026-11-08.
- U.S. Access Board, Guide to the ADA Standards, Chapter 5: Stairways, accessed 2026-11-08.