Drywall types for commercial work come down to seven boards: regular, Type X, Type C, moisture and mold resistant, abuse and impact resistant, shaft liner and exterior sheathing, each tied to an ASTM standard and a code trigger.

Key takeaways

  • Type X is the fire-resistant board defined in ASTM C1396: a 5/8 in. board must reach at least 1 hour and a 1/2 in. board 45 minutes in a specified test assembly (Georgia-Pacific technical blog, 2026).
  • Type C is not defined by any ASTM standard; it is a Type X board with added glass fiber and a shrinkage-compensating additive, and 1/2 in. Type C on each side of 2-1/2 in. steel studs makes a 1-hour UL U419 wall (National Gypsum, updated June 30, 2026; USG SA100, index A-4).
  • IBC Section 2509.3 bars water-resistant gypsum backing board (green board) over a vapor retarder in showers and wherever it faces direct water; tub and shower tile needs an ASTM C1178, C1288 or C1325 backer (2025 California Building Code Section 2509, IBC text).
  • ASTM C1629 rates abuse-resistant board on 4 tests in 3 levels; Level 3 hard-body impact means at least 150 ft-lb, against 50 ft-lb for Level 1 (CGC data sheet citing ASTM C1629).
  • The producer price index for gypsum building materials was 367.032 in September 2026, 55.7% above September 2019 and 0.4% below September 2025 (BLS series WPU13710102).

What are the main drywall types?

Commercial drywall types split by job: regular board for ordinary partitions, Type X and Type C for fire-rated assemblies, moisture and mold resistant board for humid rooms, abuse-resistant board for corridors, 1 in. liner panels for shafts and glass mat sheathing behind exterior cladding. The federal master spec UFGS 09 29 00 (August 2024, Change 1 May 2025) lists every one with its standard and size.

TypeGoverning standardCommon thicknessTypical commercial useSource
Regular (white board)ASTM C13961/2 or 5/8 in., 48 in. wideNon-rated partitions and ceilingsUFGS 2.1.1
Type X (special fire resistant)ASTM C1396, Type X5/8 in. (also 1/2 in.)Fire-rated walls, ceilings, corridorsUFGS 2.1.1.3
Type C (enhanced Type X)Manufacturer proprietary; no ASTM definition1/2 or 5/8 in.Rated ceilings, shaft walls, thinner rated wallsNational Gypsum 2026
Moisture and mold resistantASTM C1396 (paper) or C1658 (glass mat); mold per ASTM D32731/2 or 5/8 in.Restrooms outside wet zones, humid rooms, board exposed during constructionVA spec 09 29 00
Glass mat tile backerASTM C11781/2 or 5/8 in., square edgesTile in tub and shower areasUFGS 2.1.3
Abuse and impact resistantASTM C1396 plus ASTM C1629 levels5/8 in. Type XCorridors, gyms, schools, hospitalsUFGS 2.1.5
Shaft liner (coreboard)ASTM C1396, Type X1 in. (or 3/4 in.), 24 in. wideElevator, stair and duct shafts; area separation wallsUFGS 2.1.13
Exterior sheathingASTM C1177 (glass mat)1/2 or 5/8 in.Behind brick veneer, EIFS and panels on steel studsUFGS 2.1.4

Three narrower boards also show up on commercial drawings: 1/4 in. flexible board for curved walls, factory-laminated sound board under ASTM C1766 for rooms that must test at STC 45 or higher, and exterior soffit board with an anti-sag core under ASTM C1396 (UFGS 09 29 00, 2.1.1.6, 2.1.1.7 and 2.1.6). Metal stud gauge and depth are a separate choice covered in our metal stud sizes guide.

What thicknesses does drywall come in for commercial jobs?

Commercial gypsum board runs from 1/4 in. to 1 in. thick, and 5/8 in. is the default: the federal spec sets Type X, Type C and abuse-resistant board at 5/8 in., while the VA master spec calls for 5/8 in. Type X unless shown otherwise. Standard panels are 48 in. wide; shaft liner panels are 24 in. wide.

Scale diagram of gypsum board edges at 1/4, 1/2, 5/8, 3/4 and 1 in. with the board types sold at each thickness Gypsum board thickness and the board types sold at each size Board edge drawn to scale (1 in. = 96 px). Sources: UFGS 09 29 00 (2024), VA spec 09 29 00, USG SA100 1/4 in. Flexible board for curved walls; base layer in some UL designs 1/2 in. Regular, moisture resistant, Type C, abuse resistant, glass mat sheathing 5/8 in. Type X, Type C, mold resistant Type X, abuse and impact resistant, sheathing 3/4 in. Shaft liner (UFGS option); high-rated cores in some 2- and 4-hour designs 1 in. Shaft liner and coreboard, 24 in. wide, Type X core, moisture-resistant paper Standard panels are 48 in. wide; liner panels are 24 in. wide. Teal = the most specified commercial thickness.
Commercial gypsum board runs from 1/4 in. flexible board to 1 in. shaft liner; 5/8 in. carries Type X, Type C and abuse-resistant board. Sources: UFGS 09 29 00 (2024), VA spec 09 29 00, USG SA100, accessed November 8, 2026.
ThicknessBoard types sold at this sizeWhere it is usedSource
1/4 in.Flexible boardCurved walls; base layer in some UL designsUFGS 2.1.1.7; USG SA100 A-7
1/2 in.Regular, moisture resistant, Type C, abuse resistant, glass mat sheathingNon-rated walls; 1-hour U419 wall with Type CUSG SA100 A-4
5/8 in.Type X, Type C, mold resistant Type X, abuse and impact resistant, sheathing, C1178 backerMost rated walls and ceilingsUFGS 2.1.1 to 2.1.5
3/4 in.Liner panel option; proprietary high-rated coresShafts; some 2- and 4-hour designsUFGS 2.1.13; USG SA100 A-22, A-90
1 in.Shaft liner and coreboard, Type X coreShaft walls, 2-layer 3-hour area separation wallsVA spec 2.1 B; WoodWorks 2022

What is the difference between Type X and Type C drywall?

Type X is a defined product: under ASTM C1396 a 5/8 in. Type X board must deliver at least 1 hour, and a 1/2 in. board at least 45 minutes, in the standard’s specified test assembly (Georgia-Pacific). Type C has no ASTM definition; makers sell it as Type X with more glass fiber and a shrinkage-compensating additive that expands in heat and tightens joints (National Gypsum, June 2026).

The practical gap shows in the listed designs. In the USG Fire-Resistant Assemblies catalog SA100 (rev. 8-13), a 1-hour UL U419 partition can use one layer of 1/2 in. Type C each side on 2-1/2 in. 25 gauge studs at 24 in. on center, about 5 psf, where the common version uses 5/8 in. Type X at about 6 psf. Our fire rated wall guide explains how those designs map to IBC wall types and hours, with door ratings and inspection points; start with the fire rated wall requirements and UL designs.

PointType XType CSource
Defined byASTM C1396No ASTM standard; maker formulationsNational Gypsum 2026
Minimum performance in the standard test5/8 in.: 1 hour; 1/2 in.: 45 minutesNot set by a standardGeorgia-Pacific
Core additivesGlass fibersMore glass fiber plus shrinkage-compensating additiveGeorgia-Pacific
1-hour U419 steel stud wall1 layer 5/8 in. each side, about 6 psf1 layer 1/2 in. each side, about 5 psfSA100 A-2, A-4
Shaft wall, UL U415System A: 1 hour, 1 in. liner plus 5/8 in. Type X, 3-1/8 in.System B: 2 hours, 1 in. liner plus 1/2 in. Type C, 3-1/2 in.SA100 A-81, A-82
Can it replace the other?Only where the listed design names itOnly where the listed design names itSA100 cross reference, p. 6

The rule that settles field arguments: the hourly rating belongs to the tested assembly, not the board. A wall is 1-hour only when the studs, board type, layers, screw spacing and joint treatment match a listed design such as UL U419, so substituting 5/8 in. Type X for a design that names Type C, or the reverse, needs the design’s approval, not a thickness match.

Which drywall types work in wet areas, and how are mold scores rated?

Wet-area board follows IBC Section 2509: tub and shower tile needs a glass mat (ASTM C1178), fiber-cement (ASTM C1288) or cementitious (ASTM C1325) backer, water closet compartment walls under tile may use water-resistant gypsum backing board, and regular board is allowed under tile elsewhere (IBC 2509.2 text in the 2025 California Building Code).

LocationWhat the code allows or requiresCode sectionSource
Tub and shower walls under tile, shower wall and ceiling panelsASTM C1178 glass mat backer, ASTM C1288 fiber-cement or ASTM C1325 cementitious backerIBC 2509.2, Table 2509.2CBC 2025 §2509
Water closet compartment walls under tileWater-resistant gypsum backing board, installed per GA-216 or ASTM C840IBC 2509.2CBC 2025 §2509
Over a vapor retarder in a shower or tub compartmentWater-resistant gypsum backing board not allowedIBC 2509.3 item 1CBC 2025 §2509
Direct water exposure or continuous high humidityWater-resistant gypsum backing board not allowedIBC 2509.3 item 2CBC 2025 §2509
Walls within 2 ft of urinals, water closets and service sinks (public toilet rooms)Smooth, hard, nonabsorbent surface to at least 4 ft above the floorIBC 1210.2.2CBC 2025 §1210
Shower compartmentsSmooth, nonabsorbent surface to at least 72 in. above the drain inletIBC 1210.2.4CBC 2025 §1210

Mold resistance is a separate test. ASTM D3273 grows mold on a board sample in a humid environmental chamber and scores it from 0 to 10, where 10 means no growth; 10 out of 10 is the best possible score (CertainTeed Extreme Impact data sheet). The VA master spec calls for glass mat board under ASTM C1658 in any location that might get wet during construction, which avoids tearing out paper-faced board soaked before dry-in.

Two install details from the federal spec matter in restrooms: steel studs behind moisture-resistant tile backer should sit no more than 16 in. on center, and ceiling supports for moisture-resistant board no more than 12 in. on center (UFGS 09 29 00, note to 2.1.2). The 1210.2.2 rule usually means tile, FRP or another hard finish over the board, so the board choice and the finish choice go on the same drawing.

How are abuse and impact resistant boards rated?

ASTM C1629 classifies abuse-resistant gypsum board on four separate tests (surface abrasion, indentation, soft-body impact and hard-body impact) and assigns Level 1, 2 or 3 for each, with Level 3 the toughest. A board can be Level 3 for impact and Level 1 for indentation, so a spec that just says “abuse resistant” buys whatever the lowest-cost product scores.

Test (ASTM C1629)Level 1Level 2Level 3Source
Surface abrasion, maximum depth after 50 wire-brush cycles0.126 in.0.059 in.0.010 in.CGC data sheet
Indentation, maximum depth0.150 in.0.100 in.0.050 in.CGC data sheet
Soft-body impact (60 lb bag), minimum energy90 ft-lb195 ft-lb300 ft-lbCGC data sheet
Hard-body impact (swinging ram), minimum energy50 ft-lb100 ft-lb150 ft-lbCGC data sheet
ASTM C1629 minimum impact energy by classification levelBar chart: soft-body impact minimums of 90, 195 and 300 ft-lb and hard-body minimums of 50, 100 and 150 ft-lb for Levels 1 to 3.0100200300400ft-lb90.050.0Level 1195100Level 2300150Level 3Soft-body impactHard-body impact
A Level 3 board must survive three times the hard-body energy of a Level 1 board: 150 ft-lb against 50 ft-lb. Source: ASTM C1629 levels in a CGC data sheet, accessed November 8, 2026.

Published results for 5/8 in. Type X abuse boards show the spread. One maker’s abuse-resistant Type X lists abrasion Level 2 (Level 3 once primed and painted twice in semigloss), indentation Level 1, soft-body Level 2 and hard-body Level 1 (USG spec WB3009); a fiberglass-mesh impact board lists abrasion Level 3, indentation Level 1 and Level 3 for both impact tests at 2.8 lb per sq ft (CertainTeed data sheet).

Spec writers at the Department of Defense add two limits: abuse-resistant board needs at least 20 gauge steel framing behind it, and a polycarbonate-backed panel acts as a vapor barrier that may not suit every wall and climate (UFGS 09 29 00, note to 2.1.5). The same spec sets hard-body impact at Level 1 minimum and leaves abrasion and indentation at Level 1, 2 or 3 for the designer to pick by room.

What are shaft liner and exterior sheathing boards?

Shaft liner is 1 in. thick Type X coreboard, 24 in. wide with moisture-resistant paper, set vertically between J-runners with C-H studs and finished from the corridor side (VA spec 3.4). IBC Section 713.4 requires 2-hour shaft enclosures that connect 4 or more stories and 1 hour below that (WoodWorks, March 2022).

SystemRatingBuildThickness, weightSource
UL U415 System A1 hour1 in. liner, 2-1/2 in. C-H studs 25 ga at 24 in., 5/8 in. Type X face3-1/8 in., 8 psfSA100 A-81
UL U415 System B2 hours1 in. liner, 2-1/2 in. C-H studs, 1/2 in. Type C face layers3-1/2 in., 9 psfSA100 A-82
UL U415 System G3 hours1 in. liner, 2-1/2 in. C-H studs, 5/8 in. Type C face layers4-3/8 in., 13 psfSA100 A-88
Glass mat sheathingNot a rating by itself1/2 or 5/8 in. ASTM C1177 board, felt or WRB over it, joints sealed12-month delamination warranty in the federal specUFGS 2.1.4

Exterior gypsum sheathing on steel stud backup walls is a glass mat board under ASTM C1177 with a water-resistant core. The federal spec asks the maker to warrant it for at least 12 months against delamination from direct weather and requires a continuous asphalt felt layer over its face (UFGS 09 29 00, 2.1.4), which sets how long a building can sit wrapped before cladding goes on.

Where does the building code require each drywall type?

Building codes name a board type in three places: fire-resistance-rated assemblies, which must match a tested design; wet areas under IBC Sections 1210 and 2509; and shafts under IBC 713.4. Abuse resistance and finish level are owner and spec choices, not code minimums.

LocationBoard the code or spec points toRuleSource
Fire barrier, fire partition, rated corridor or ceilingBoard named in the listed design, usually 5/8 in. Type X or Type CIBC Chapter 7, tested designour fire rated wall guide; SA100
Shaft through 4 or more stories2-hour shaft wall, 1 in. liner systemIBC 713.4WoodWorks 2022
Tub and shower tileC1178, C1288 or C1325 backerIBC 2509.2CBC 2025
Public toilet room near fixturesHard nonabsorbent finish to 4 ft over the boardIBC 1210.2.2CBC 2025
VA hospital corridors and public areas5/8 in. Type X; Level 4 finish where open to public viewVA master specVA spec 09 29 00
Federal (DoD) projects with expected abuseC1629 board, hard-body Level 1 minimumUFGS 2.1.5 (federal only)UFGS 09 29 00

The construction type and occupancy group of the building drive how many hours each wall needs; our types of construction guide and occupancy classification guide cover those two inputs, which come before any board choice.

What are drywall finish levels 0 to 5?

Gypsum Association document GA-214-2021 defines six levels of finish, from Level 0 (no tape) to Level 5 (a skim coat over the entire surface). Each level adds work to the one before, and the right level depends on the paint sheen and lighting, not the board type.

Stepped diagram of GA-214 drywall finish levels 0 to 5 with the work added and the typical use at each level GA-214 levels of finish: what each level adds and where it goes Sources: Gypsum Association GA-214-2021 as summarized by National Gypsum (2022); UFGS 09 29 00, 3.4 Level 0 Level 1 Level 2 Level 3 Level 4 Level 5 No tape Tape in compound + 1 coat on fasteners + 2nd joint coat + 2 coats on flat joints + skim coat over whole surface Plenum Tile backer Heavy texture Flat paint Gloss, lighting Temporary Each level includes all the work of the level before it.
Each GA-214 level adds work to the last, from no tape at Level 0 to a full skim coat at Level 5. Sources: GA-214-2021 as summarized by National Gypsum (2022); UFGS 09 29 00, 3.4.
LevelWork includedRecommended useSource
0No tape, finishing or accessoriesTemporary construction, decoration undecidedNational Gypsum on GA-214
1Tape embedded in joints and interior anglesPlenums above ceilings, smoke barriers, areas not open to viewNational Gypsum; UFGS 3.4
2Level 1 plus a thin coat over joints and one coat over fastenersTile substrate, warehouses, storage, garagesNational Gypsum
3Level 2 plus a separate coat over joints, two over fastenersHeavy or medium texture, heavy commercial wallcoveringNational Gypsum
4Two coats on flat joints, three over fastenersFlat paint, light texture, wallcoveringNational Gypsum
5Level 4 plus a skim coat over the whole surfaceGloss, semigloss or eggshell paint, dark colors, critical lightingUFGS 3.4.1

Specs differ on the default. The federal spec finishes everything to Level 5 unless stated otherwise and requires Level 5 under eggshell, semigloss or gloss paint or strong side lighting (UFGS 09 29 00, 3.4), while the VA spec uses Level 4 for finished areas open to public view (VA spec 3.5). The level belongs in the painting spec too; our commercial painting guide lists the sheen choices that push a wall from Level 4 to Level 5.

What does drywall cost, and how have gypsum prices moved?

Gypsum board prices rose sharply in 2021 and 2022 and have been flat since 2024: the BLS producer price index for gypsum building materials read 367.032 in September 2026 (preliminary), 55.7% above September 2019 and 0.4% below September 2025 (BLS PPI WPU13710102).

September ofPPI, gypsum building materialsChange from prior SeptemberSource
2018262.3BLS
2019235.8-10.1%BLS
2020235.0-0.3%BLS
2021295.370+25.7%BLS
2022355.246+20.3%BLS
2023349.007-1.8%BLS
2024367.312+5.2%BLS
2025368.591+0.3%BLS
2026 (preliminary)367.032-0.4%BLS
Gypsum building materials producer price index, September 2018 to 2026Line chart: the gypsum building materials index fell to 235.0 in September 2020, rose to 355.246 by 2022 and held near 367 from 2024 to 2026.200250300350400index201820192020202120222023202420252026
The gypsum building materials index rose 25.7% in the year to September 2021 and 20.3% the next year, then held near 367 from 2024 to 2026. Source: BLS PPI WPU13710102, accessed November 8, 2026.

An index is not a price, but it escalates an old budget line. The worked example below moves a $50,000 board material allowance priced in an earlier year to September 2026 using the index ratio; it is an illustration of the arithmetic, not a quote.

InputValueNote
Board material allowance, priced September 2019$50,000Example figure
Index, September 2019235.8BLS WPU13710102
Index, September 2026367.032Preliminary
Escalation factor367.032 / 235.8 = 1.557Rounded
Same allowance in September 2026$77,827$50,000 x 1.557
Same allowance priced September 2025$49,789 in September 2026Factor 367.032 / 368.591 = 0.996

Installed cost sits in the interiors package rather than per sheet. Cushman & Wakefield’s 2026 office fit-out guide puts drywall, acoustic ceilings and carpentry at $26.29 per sq ft, 11.9% of a $220.62 per sq ft New York hard cost (Cushman & Wakefield, 2026); our office renovation cost guide breaks down the rest of that budget. A Level 5 skim coat adds a full finishing pass over every wall, so board type and finish level should be priced as separate lines.

We looked for a dated public bid tabulation or state contract with a per-sheet unit price for 5/8 in. Type X and could not open one that we could verify, so this page gives no per-sheet dollar figure. For live numbers, ask bidders to price the board as a separate unit-price line by type and thickness, and compare bids line by line with our guide to comparing construction bids.

Which drywall type should you specify?

Pick the board in this order: fire-rated design first, then water exposure, impact, shaft or exterior location, and humidity. The first rule that applies decides the board; regular ASTM C1396 board is the answer only when none do.

Flowchart of five questions that pick a drywall type: fire rating, water, impact, shaft or exterior, humidity Which drywall type? Ask these five questions in order 1. Is the wall or ceiling in a listed fire-rated design (UL, GA-600)? Yes: use the exact board the design names (5/8 in. Type X or Type C) No, or also 2. Is it a tub or shower wall, or exposed to direct water? Yes: ASTM C1178, C1288 or C1325 backer (IBC 2509.2), not green board 3. Will carts, beds, balls or vandals hit the wall? Yes: ASTM C1629 board, name the level for each of the 4 tests 4. Is it a shaft, or the outside face of an exterior wall? Shaft: 1 in. liner panel system Exterior: ASTM C1177 sheathing 5. Humid room, or board wet during construction? Yes: moisture and mold resistant board (ASTM D3273 score of 10) None of these: regular ASTM C1396 board
Answer five questions in order and the first yes picks the board; regular ASTM C1396 board only when all five are no. Sources: IBC 2509, ASTM C1629, UFGS 09 29 00, USG SA100.
IfThen specifyWhySource
The wall or ceiling is part of a listed fire-rated designThe exact board named in that design (5/8 in. Type X or 1/2 or 5/8 in. Type C)The rating belongs to the tested assemblyUSG SA100
Tile goes on a tub or shower wallASTM C1178, C1288 or C1325 backerIBC 2509.2; green board barred by 2509.3CBC 2025 §2509
Tile goes on water closet compartment wallsWater-resistant gypsum backing board is allowedIBC 2509.2CBC 2025 §2509
Carts, beds or balls will hit the wallASTM C1629 board with a level named for each of the 4 tests; 20 ga studs minimumGeneric “abuse resistant” buys Level 1UFGS 2.1.5
A shaft connects 4 or more stories2-hour 1 in. liner shaft wall, such as UL U415 System BIBC 713.4WoodWorks 2022
Brick, EIFS or panels go over steel studsASTM C1177 glass mat sheathing, 1/2 or 5/8 in., with felt or WRBWeather exposure before claddingUFGS 2.1.4
Board may get wet before dry-inASTM C1658 glass mat boardPaper-faced board grows mold when soakedVA spec 3.1 C
Paint is eggshell or glossier, or lighting rakes the wallLevel 5 finishJoints photograph through sheenUFGS 3.4.1
The room needs a tested STC of 45 or moreFactory-laminated board under ASTM C1766Sound-rated assembliesUFGS 2.1.6

Write the board type, thickness, ASTM designation and finish level on the partition schedule and in the submittals so substitutions are caught before the board arrives; our construction submittals guide shows how that review works.

What several guides say vs what the primary source says

Several top-ranking drywall guides, most written for homeowners, give board ratings and uses that the standards and code text do not support. The table compares 4 common claims with the primary source.

What several guides sayWhat the primary source saysSource
“Type X has a 1-hour fire rating” (a guide published January 2025)ASTM C1396 sets a 1-hour minimum for 5/8 in. Type X only in its specified test assembly; a real wall’s rating comes from its listed designGeorgia-Pacific; USG SA100
“Type C is rated 2 to 4 hours” (a guide dated 2017)Type C has no ASTM definition and no hours of its own; 1/2 in. Type C each side gives 1 hour in UL U419National Gypsum 2026; SA100 A-4
Green board suits bathrooms and kitchensIBC 2509.3 bars it from direct water, continuous high humidity and over a vapor retarder in showersCBC 2025 §2509.3
Paperless or abuse-resistant board is simply “more durable”ASTM C1629 rates 4 properties at 3 levels each; products differ test by testCGC data sheet; USG WB3009

Board is hung on the steel framing sized in our metal stud sizes guide, and ceilings below it are priced in our drop ceiling cost guide.

How we compiled this

We read 2 public master specifications (UFGS 09 29 00 and VA 09 29 00), IBC Sections 1210 and 2509 as printed in the 2025 California Building Code, 5 manufacturer data sheets, specs and catalogs, 3 manufacturer technical articles on Type X, Type C and GA-214, and BLS producer price data, all accessed November 2026. ASTM and ICC sites blocked direct reading, so standard thresholds come from manufacturer documents that reproduce them; we did not test any product.

Frequently asked questions

What type of drywall is used in commercial buildings?

Most commercial walls and ceilings use 5/8 in. Type X gypsum board under ASTM C1396, because so many partitions sit in fire-rated designs. The VA master spec calls for 5/8 in. Type X unless the drawings show otherwise. Shafts add 1 in. liner panels, wet zones add glass mat or cement backers, and busy corridors add ASTM C1629 abuse-resistant board.

Is Type X drywall required in commercial construction?

Not everywhere. The building code requires whatever board the listed fire-rated design names, which is usually 5/8 in. Type X or Type C, in rated walls, ceilings, corridors and shafts. A non-rated partition between two offices in the same tenant space can use regular ASTM C1396 board, although many owners standardize on Type X to keep one board on site.

Can moisture-resistant drywall go in a shower?

No. IBC Section 2509.3 bars water-resistant gypsum backing board over a vapor retarder in shower or tub compartments and anywhere with direct water exposure or continuous high humidity. Tub and shower walls under tile need an ASTM C1178 glass mat backer, an ASTM C1288 fiber-cement board or an ASTM C1325 cementitious backer unit.

What is the difference between Type X and Type C drywall?

Type X is defined in ASTM C1396: 5/8 in. board must reach at least 1 hour and 1/2 in. board 45 minutes in the standard test assembly. Type C has no ASTM definition; makers add more glass fiber and a shrinkage-compensating additive. In UL U419, one layer of 1/2 in. Type C each side makes a 1-hour steel stud wall.

What drywall finish level is standard for commercial walls?

Level 4 is the common default for painted walls with flat paint; the VA spec uses Level 4 for finished areas open to public view. The federal UFGS 09 29 00 defaults to Level 5 and requires it under eggshell, semigloss or gloss paint or strong side lighting. Plenums above ceilings only need Level 1.

What thickness is shaft liner drywall?

Shaft liner, also called coreboard, is 1 in. thick and 24 in. wide with a Type X core and moisture-resistant paper, with 3/4 in. as an alternate in the federal spec. In UL U415 it forms 1-hour to 4-hour shaft walls built from the corridor side; IBC 713.4 requires 2 hours for shafts connecting 4 or more stories.

Sources

Last reviewed November 2026 by the CB&C Editorial Team. See our editorial standards.